Power Supply Current Measurement for Memory

Power Supply Current Measurement for Memory is a algorithm IP to measure the power supply current for memory ICs.

  • Measures the power supply current for memory ICs that sets to a certain operating condition by inputting pattern data.
  • Measures the average power supply current easily.
  • Performs pass/fail judgment for the power supply current value by setting the specified upper and lower limit values.
  • Measures the power supply current with measurement precision as necessary by selecting the measurement range.
  • Measures the parallel drive supply micro-current.

Revision contents on Rev 1.06.03

Condition Table Memory_TypeF License(PCXA01-3004)

When VIH/VIL is outside the range of the voltage generation or the voltage generation amplitude in [Condition Table], the specification has been changed to generate an error.

Features

Power Supply Current Measurement for Memory is a algorithm IP to measure the power supply current for memory ICs.

  • Measures the power supply current for memory ICs that sets to a certain operating condition by inputting pattern data.
  • Measures the average power supply current easily.
  • Performs pass/fail judgment for the power supply current value by setting the specified upper and lower limit values.
  • Measures the power supply current with measurement precision as necessary by selecting the measurement range.
  • Measures the parallel drive supply micro-current.
  • Supports the following licenses.
    • Condition Table Memory_TypeF License(PCXA01-3004). (Manual)
    • High Resolution Timing Memory_TypeF License(PCXA01-3006). (Manual)

Add to Cart

Product GroupAlgorithm IP
CodePCXA01-M3003
Link
ManufacturerADVANTEST CORPORATION
Applicable Equipment
  • CX1000P MEMORY_TYPE_F
  • CX1000D MEMORY_TYPE_F
Condition Table Memory_TypeF License

High Resolution Timing Setting for Memory_TypeF License

Revisions

Released atNumberDescription
August 28, 20191.06.03

Condition Table Memory_TypeF License(PCXA01-3004)

When VIH/VIL is outside the range of the voltage generation or the voltage generation amplitude in [Condition Table], the specification has been changed to generate an error.

June 19, 20191.06.02
  1. If [Change Measure Range A at Measurement]is enabled (check box is checked) on the [Measure Condition] tab, it was not possible to repeat measurement with the pattern sequence instruction "WAIT", so it was corrected.
  2. The following items supported in Rev1.06.00 were not included in Rev 1.06.01, so they have been fixed to work correctly.
    • Using 8V range, the following run-time error occurred in some cases.
      “Unkown source range value ‘8.0V’ in getSourceRange”
      This issue has been fixed so that this error does not occur under normal execution.
    • Add the function to acquire current measurement value of RVS.
April 24, 20191.06.01
  • The Stabilization Wait Time setting was set longer than the setting value. Set it correctly.
February 08, 20191.06.00
  • Using 8V range, the following run-time error occurred in some cases. “Unkown source range value ‘8.0V’ in getSourceRange” This issue has been fixed so that this error does not occur under normal execution.
  • Supports pattern sequence instruction “WAIT”.
  • Add the function to acquire current measurement value of RVS.
December 06, 20161.05.00

Support “power-off control” function on “Flow Item List Area” in Expert Mode.