1. Summary of revision
- Revision number
- Rev 2.25.00
- Reason for revision
- Addition of function, Functional improvement, Fixing issue
2. Addition of functions
2.1 CT Command
(1) LoggingMode option for CT_DataLogSet.bat was supported
LoggingMode option for CT_DataLogSet.bat was supported.
- Target firmware
- CX1000_MCU
3. Improved functions
3.1 Setup and Execution
(1) The driver wave drawn in Signal Condition was improved
The driver wave drawn in Signal Condition was imporved as below : - It is drawn with dashed line before the level is settled, and it is drawn with solid line after the level settled. - It is drawn with gray line before the driver is enabled, and it is drawn with red line after the driver is enabled.
- Target firmware
- CX1000_MCU
3.2 Analysis Tools
(1) Performance improvement for loading pattern comments
Performance for loading pattern comments was improved.
- Target firmware
- CX1000_MCU
4. Fixed issues
4.1 CT Command
(1) The measurement item name containing some spaces could not be specified as a command argument
The measurement item name containing some spaces could not be specified as a command argument for the following CT commands:
- CT_FlowStart.bat
- CT_FlowStartNoWait.bat
- CT_MeasrureItemStart.bat
- CT_MeasureItemStartNoWait.bat
- CT_MeasureItemSelect.bat
- CT_FlowItemStart.bat
- CT_FlowItemStartNoWait.bat
- Behavior after improvement
- The double-quoted measurement item name containing some spaces can be specified.
- Revisions in which this phenomenon occurs
- Rev 2.20.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
(2) CT Command could be unusable if the Operation Wondow for CX1000 was running
CT Command could be unusable if the Operation Wondow for CX1000 was running.
- Behavior after improvement
- CT Command can be used properly.
- Revisions in which this phenomenon occurs
- Rev 2.20.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
4.2 Variable
(1) An error occured when the array of strings was renamed
An error occurred when the array of strings was renamed if the initial values for the array elements were specified by index numbers.
- Behavior after improvement
- The variable name can be renamed properly.
- Revisions in which this phenomenon occurs
- Rev 2.20.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
- (2) The variable which definition had not been completed was displayed on
- the Select Variable
- dialog box in the Expert Mode
- The variable which definition had not been completed was displayed on
- the Select Variable
- dialog box which was used to select the variable for the Branch Switch Value
- or the interpose processing in the Expert Mode.
- Behavior after improvement
- The variable which definition has not been completed is not displayed. The measurement cannot be started if there is such variable on the Define Variables
- dialog box.
- Revisions in which this phenomenon occurs
- Rev 2.20.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
4.3 Analysis Tools
(1) The datalog was set disabled by interrupting the analysis tool execution
The datalog was set disabled by interrupting the analysis tool execution.
- Behavior after improvement
- The datalog is not set disabled in the situation above.
- Revisions in which this phenomenon occurs
- Rev 2.22.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU
(2) If there was the measurement item whose name was ended with “shmoo“, Shmoo could not be execute
If the measurement item named “XXX” and the measurement item named “XXX_shmoo” existed, the Shmoo for “XXX” could not be executed in the Expert Mode. (XXX is an arbitrary string)
- Behavior after improvement
- Shmoo works properly in the situation above.
- Revisions in which this phenomenon occurs
- Rev 2.22.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
(3) Analysis tools could not be stopped executing by stop button
Analysis tools could not be stopped executing by stop button.
- Behavior after improvement
- The above behavior is improved.
- Revisions in which this phenomenon occurs
- Rev 1.00.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
4.4 Flow Execution (Standard Mode)
(1) The work project which had been saved after deleting some measurement items could not be opened
- The work project which had been saved after deleting the measurement item that had been selected in the Setup and Execution
- could not be opened.
- Behavior after improvement
- The saved work project can be opened properly.
- Revisions in which this phenomenon occurs
- Rev 2.24.00 to Rev 2.24.01
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F