CloudTesting™ Lab 2.23.00

Reason for revision

Addition of function, Functional improvement, Fixing issue

Addition of functions

Work Project

Additional functions for [Open Work Project] dialog box

Following functions were added: - Open Work Project dialog box can be launched from Startup Window. - The [Root Folder] setting that has been set previously is applied when starting the dialog.

Target firmware
CX1000_MCU, CX1000_MEMORY_TYPE_F

Additional function for [Continue Existing Work Project]

The capability to delete histories of saved work projects was added.

Target firmware
CX1000_MCU, CX1000_MEMORY_TYPE_F

Pattern Compiler

Graphical user interface(GUI) to compile pattern sources

Pattern sources can be compiled with GUI.

Target firmware
CX1000_MCU, CX1000_MEMORY_TYPE_F

CT Commands

CT_Start.bat

The command to launch the main window and to load specified work project was added.

Target firmware
CX1000_MCU, CX1000_MEMORY_TYPE_F

Improved functions

Variable

Plus sign in exponent notation

The value with plus sign is allowed for the exponent part in exponent notation.

Target firmware
CX1000_MCU, CX1000_MEMORY_TYPE_F

Setup and Execution

Improved processing time for CX1000 MCU pattern

Following processing times were improved. - Pre processing time to execute pattern. - Processing time to read pattern label.

Target firmware
CX1000_MCU

Maintenance Program

Improvement for uneven execution time

Uneven execution time of self-check among others were improved.

Target firmware
CX50_GENERAL

Fixed issues

Variable

The variables that were not used could not be deleted.

Even if all measure items that were using some variables were deleted, the message intending the use of the variables had been shown, the variables could not be deleted.

Behavior after improvement
In the condition above, they can be deleted.
Revisions in which this phenomenon occurs
Rev 2.20.00 to Rev 2.22.03
Target firmware
CX1000_MCU, CX1000_MEMORY_TYPE_F

Setup and Execution

Error while applying a signal condition

Error occurred while executing measurement if all of the following conditions were satisfied in the signal condition window: - []

Behavior after improvement
In the condition above, it works properly.
Revisions in which this phenomenon occurs
Rev 2.20.00 to Rev 2.22.03
Target firmware
CX1000_MEMORY_TYPE_F

Match judgement did not work.

When Match1, Match2, or Match3 was specified as match method for the pin that had connected to the channel 33 or following channels, match judgement for the pin did not work.

Behavior after improvement
Match judgement works for every pins.
Revisions in which this phenomenon occurs
Rev 2.10.00 to Rev 2.22.03
Target firmware
CX1000_MEMORY_TYPE_F

Expert Mode

The modified conditions that had not been confirmed yet were discarded.

The modified conditions that had not been confirmed yet were discarded when editing pin definitions in Expert Mode.

Behavior after improvement
The modified conditions are confirmed when the [Pin Definitions] dialog is opened.
Revisions in which this phenomenon occurs
Rev 2.20.00 to Rev 2.22.03
Target firmware
CX1000_MCU, CX1000_MEMORY_TYPE_F