Reason for revision
Addition of function, Functional improvement, Fixing issue
Addition of functions
Work Project
Additional functions for [Open Work Project] dialog box
Following functions were added: - Open Work Project dialog box can be launched from Startup Window. - The [Root Folder] setting that has been set previously is applied when starting the dialog.
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
Additional function for [Continue Existing Work Project]
The capability to delete histories of saved work projects was added.
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
Pattern Compiler
Graphical user interface(GUI) to compile pattern sources
Pattern sources can be compiled with GUI.
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
CT Commands
CT_Start.bat
The command to launch the main window and to load specified work project was added.
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
Improved functions
Variable
Plus sign in exponent notation
The value with plus sign is allowed for the exponent part in exponent notation.
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
Setup and Execution
Improved processing time for CX1000 MCU pattern
Following processing times were improved. - Pre processing time to execute pattern. - Processing time to read pattern label.
- Target firmware
- CX1000_MCU
Maintenance Program
Improvement for uneven execution time
Uneven execution time of self-check among others were improved.
- Target firmware
- CX50_GENERAL
Fixed issues
Variable
The variables that were not used could not be deleted.
Even if all measure items that were using some variables were deleted, the message intending the use of the variables had been shown, the variables could not be deleted.
- Behavior after improvement
- In the condition above, they can be deleted.
- Revisions in which this phenomenon occurs
- Rev 2.20.00 to Rev 2.22.03
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F
Setup and Execution
Error while applying a signal condition
Error occurred while executing measurement if all of the following conditions were satisfied in the signal condition window: - []
- Behavior after improvement
- In the condition above, it works properly.
- Revisions in which this phenomenon occurs
- Rev 2.20.00 to Rev 2.22.03
- Target firmware
- CX1000_MEMORY_TYPE_F
Match judgement did not work.
When Match1, Match2, or Match3 was specified as match method for the pin that had connected to the channel 33 or following channels, match judgement for the pin did not work.
- Behavior after improvement
- Match judgement works for every pins.
- Revisions in which this phenomenon occurs
- Rev 2.10.00 to Rev 2.22.03
- Target firmware
- CX1000_MEMORY_TYPE_F
Expert Mode
The modified conditions that had not been confirmed yet were discarded.
The modified conditions that had not been confirmed yet were discarded when editing pin definitions in Expert Mode.
- Behavior after improvement
- The modified conditions are confirmed when the [Pin Definitions] dialog is opened.
- Revisions in which this phenomenon occurs
- Rev 2.20.00 to Rev 2.22.03
- Target firmware
- CX1000_MCU, CX1000_MEMORY_TYPE_F