How to change the power supply voltage synchronized with the pattern in functional tests

Question

Is it possible to change the power supply voltage synchronized with the pattern address in functional tests?

Answer

It is possible to use Functional Testing IP.
Create a test with the following steps.

(1)Divide the pattern to end just before the address that you want to change the power supply voltage.
(2)Create a test that executes the pattern of before the voltage change(A) and create a test that executes the pattern of after the voltage change(B). “Power Sequence Off” has to set “DISABLE” at test B.
(3)Set the voltage of before change to test A and set the voltage of after change to test B.
(4)Execute the tests continuously.

Please refer to “CX1000 User’s manual” for details of this method.
.

Updated at
January 01, 2017