1. Summary of revision
Revision number | Reason for revision |
---|---|
2.42.00 | Addition of function, Functional improvement, Fixing issue |
2. Addition of functions
2.1 Message Display Area
(1) The options when the existing logging file is overwritten
The following options are added when the existing logging file is overwritten.
- The logging file is overwritten every flow execution.
- A backup file is created when the logging file is overwritten.
Target firmware |
---|
CX1000_MCU, CX1000_MEMORY_TYPE_F |
For details, refer to the following sections in the “CX1000 User’s Manual.”
- “5.10 Setting the message display area”
- “Overwriting existing file when creating the logging file”
3. Improved functions
3.1 Pattern Compiler
(1) The options for the compile from the graphical user interface (GUI)
The following options are added.
- Separates the pattern source file folder from the work project folder
- Changes the output folder of the pattern object files
Target firmware |
---|
CX1000_MCU |
For details, refer to the following sections in the “CX1000 User’s Manual.”
- “4.50 Compiling Pattern Source File on Pattern Compiler Window”
- “4.50.2 Executing Compilation”
- “Setting Options for CX1000_MCU Firmware”
- “4.50.2 Executing Compilation”
(2) The option for the compile from the command prompt
The ‘-o’ option can be used to specify the output folder of the pattern object files.
Target firmware |
---|
CX1000_MCU |
For details, refer to the following sections in the “CX1000 User’s Manual.”
- “4.11 Creating Pattern Programs”
- “Compiling the pattern source file”
- “Compiling from the command prompt”
- “Compiling the pattern source file”
3.2 Flow Execution
(1) The feature to copy multiple measurement items by dragging
The following feature is supported in Standard Mode and Expert Mode.
- Multiple measurement items are copied by dragging.
Target firmware |
---|
CX1000_MCU, CX1000_MEMORY_TYPE_F |
For details, refer to the following sections in the “CX1000 User’s Manual.”
- Standard Mode
- “5.1 Executing Flow”
- “Moving Measurement Items and Specifying Order of Execution”
- “5.1 Executing Flow”
- Expert Mode
- “8.4 Flow Item List Area”
- “Moving Flow Items”
- “Drag and Drop”
- “Moving Flow Items”
- “8.4 Flow Item List Area”
4. Fixed issues
4.1 Maintenance Program
(1) An error might occur while writing data when the level calibration (DC Calibration) was executed.
An error might occur while writing data to the CloudTesting™ station when the level calibration (DC Calibration) was executed.
- Behavior after improvement
The data is successfully written to the CloudTesting™ station.
Revisions in which this phenomenon occurs | Target firmware |
---|---|
Rev 1.00.00 to 2.40.01 | CX1000_MCU, CX1000_MEMORY_TYPE_F |
4.2 Analysis Tools
(1) The measurement items specified in the Final Measure Item were not executed when the execution of the Analysis Tools was interrupted.
The measurement items specified in the Final Measure Item were not executed when the execution of the Analysis Tools was interrupted.
- Behavior after improvement
The specified measurement items are executed when the execution of the Analysis Tools was interrupted.
Revisions in which this phenomenon occurs | Target firmware |
---|---|
Rev 2.41.00 to 2.41.01 | CX1000_MCU, CX1000_MEMORY_TYPE_F |
4.3 Setup and Execution
(1) An error occurred when executing the Shmoo Algorithm with Measure Item Execution IP.
An error occurred when executing the Shmoo Algorithm with Measure Item Execution IP.
- Behavior after improvement
No error occurs under the above conditions.
Revisions in which this phenomenon occurs | Target firmware |
---|---|
Rev 2.41.00 to 2.41.01 | CX1000_MCU, CX1000_MEMORY_TYPE_F |
4.4 Startup
(1) When starting with CX1000D S2-LINK, no error occurred even if the firmware revisions of MASTER and SLAVE were different.
When starting with CX1000D S2-LINK, no error occurred even if the firmware revisions of MASTER and SLAVE were different.
- Behavior after improvement
An error occurs if the MASTER and SLAVE have different firmware revisions.
Revisions in which this phenomenon occurs | Target firmware |
---|---|
Rev 2.01.00 to 2.41.01 | CX1000_MCU |
4.5 Expert Mode
(1) The execution of the [Execute Select Item & Suspend] hung-up.
When the power supply condition for RVS had been displayed, the execution of the [Execute Select Item & Suspend] hung-up
- Behavior after improvement
The [Execute Select Item & Suspend] is successfully executed.
Revisions in which this phenomenon occurs | Target firmware |
---|---|
Rev 2.20.00 to 2.41.01 | CX1000_MCU, CX1000_MEMORY_TYPE_F |
(2) The pin definitions were cleared and the measurement could not be executed.
All the pin definitions were cleared and the measurement could not be executed after the following procedure in the [Pin Definitions] dialog box.
- Define a pin that is out of hardware specifications, such as a channel number out of range.
- Click [OK]. An error dialog appears.
- Click [Cancel] to close the [Pin Definitions] dialog box.
- Behavior after improvement
If an error occurs when clicking [OK], the [Pin Definitions] dialog box does not close. To close the dialog box, set the channel number within the hardware specifications.
Revisions in which this phenomenon occurs | Target firmware |
---|---|
Rev 2.20.00 to 2.41.01 | CX1000_MCU, CX1000_MEMORY_TYPE_F |