Important notification about defect of Digital Output Capture IP[PCXA01-M1031]

October 11, 2018

Thank you for using CloudTesting(TM) Service.

This is an announcement on the malfunction arisen in “Digital Output Capture IP”.

Digital Output Capture IP may not operate correctly under specific measurement conditions.

Equipment in matter

CX1000P CX1000_MCU, CX1000D CX1000_MCU, CX1000D S2-LINK CX1000_MCU

IP in matter

Digital Output Capture IP[PCXA01-M1031]

Revision in matter

R1.00.00 or later

Detail of the malfunction

The measurement item with all of the following conditions cannot measure correctly.

  • [Save captured data as numerical data] is disabled
  • [Address Selection] or [Cycle Selection] is specified for [Capture Mode]

If you have any question, please contact Helpdesk.

Resolution

The fixed revision of the subject IP is under preparation and will be released in December.

It is our regret that the bug brings about inconveniences to our customers. We would highly appreciate that we would have your consecutive subscription of our services.